ServiceNomad RV · Knowledge
Onan Generator Fault Code 36
Onan generator Fault Code 36 is an immediate shutdown code that indicates the generator detected an over-frequency or under-frequency condition, often coupled with load imbalance or fuel delivery issues. When Fault 36 appears, the generator will crank, start, run briefly, and then shut down with a flash code (three flashes, pause, six flashes). Understanding what triggers this fault helps you determine whether it's a simple fuel issue or a deeper electronic problem.
What Fault 36 Means
Onan generators produce AC power at a specific frequency (60 Hz in North America). The control board constantly monitors the output frequency—if it deviates significantly from 60 Hz (usually below 58 Hz or above 62 Hz), it assumes something is wrong with the engine speed (RPM) control or the load being applied. Fault 36 is triggered when the frequency is unstable or incorrect for more than a few seconds. Frequency is directly tied to engine RPM. If the engine cannot maintain proper speed due to fuel starvation, governor failure, or excessive load, frequency will drop. Conversely, if the engine overspeeds due to governor malfunction, frequency will spike. In either case, the board shuts down to protect connected appliances from out-of-spec power.
Fuel Delivery and Carburetor Issues
The most common cause of Fault 36 is fuel starvation—the engine starts, runs on the fuel in the carburetor bowl, and then starves out as it cannot draw fresh fuel fast enough. This causes RPM to drop, frequency to sag, and the board throws Fault 36. Common fuel-related causes include a clogged fuel filter, kinked or collapsed fuel line, failing fuel pump (if equipped), or a carburetor with clogged jets. If your generator hasn't run in several months, fuel may have gummed up the carburetor jets. Running the generator under load for a few cycles with fresh fuel and a fuel system cleaner can sometimes clear minor varnish buildup. However, if the problem persists, the carburetor will need professional cleaning or replacement.
Governor Adjustment and Control
Onan generators use a mechanical governor to maintain constant RPM regardless of load. The governor senses engine speed through centrifugal weights or electronic sensors and adjusts the throttle to compensate. If the governor linkage is sticking, the throttle cable is frayed, or the governor itself is out of adjustment, the engine will hunt (surge) and throw Fault 36 as frequency oscillates. Governor adjustment requires specialized tools and knowledge of the specific Onan model. A technician will mechanically adjust the governor while monitoring frequency with a load bank to ensure stable operation under varying loads.
Load Imbalance and Air Filter Restriction
If you're running a single high-draw appliance (like an RV AC) on one leg of a split-phase generator, you may create a load imbalance severe enough to trigger Fault 36. The generator tries to compensate for the unbalanced load, RPM fluctuates, and the control board shuts down. Similarly, a severely clogged air filter can restrict airflow to the carburetor, causing a lean fuel mixture and RPM instability. Always check and clean or replace the air filter before diagnosing deeper issues. Ensure loads are balanced across both legs of the generator if possible—for example, run the AC and the microwave instead of just the AC alone.
⚠️ Safety Notes
- Never attempt to adjust the governor or carburetor while the generator is running—rotating parts can cause serious injury.
- Fuel system work requires proper ventilation and fire safety precautions—gasoline vapors are highly flammable.